HY-OPTIMA<sup>®</sup> 5330 IS Gen 5 Analyzer Family

Process Analyzers

NEW! HY-OPTIMA® 5330 IS Gen 5 Analyzer Family

Intrinsically Safe Hydrogen In-Line Process Analyzer

  • Intrinsically safe design
  • 10+ years auto-calibration
  • Versatile installation options

Features

The intrinsically safe HY-OPTIMA® 5330 Analyzer family brings unparalleled reliability and durability to hydrogen in-line monitoring for diverse applications within the industrial processing sector, from chemical facilities and refineries to the burgeoning green hydrogen economy. The unit is built on H2scan’s patented, solid-state hydrogen sensing technology, the only hydrogen analyzer on the market that can provide at least 10 years of auto-calibration operation. Easy installation for stand-alone hydrogen measurement or as the hydrogen monitoring component within existing OEM devices.

  • Zero manual calibration requirements
  • Zero consumables like calibration gases
  • Zero reference or carrier gases required
  • Zero sensor replacements due to its up to 10-year lifespan
  • No false alarms from cross-sensitivity to other gases
  • 100% continuous real-time, accurate monitoring with no process downtimes
  • Tolerant of many harsh background contaminants
  • Easy connectivity via digital serial communications, analog output and relay trigger alarms for safety systems
  • Compact design for versatile installation options

Product Selection

The HY-OPTIMA 5330 Series product family includes sensor types that are designed to read hydrogen levels with CO and H2S are not present. Please see product selection table below.

Model 5331 5332 5333 5334
Hydrogen Range Low 0.03% 0.4% 0.5% 0.5%
Hydrogen Range High 10% 5% 100% 100%
CO limit 100 ppm 0 100 ppm 20%
H2S Limit 20 ppm 0 1000 ppm 3%
T90 Response Time (sec) <90 <60 <60 <90
Process Gas Temperature -20°C to 60°C (-4°F to 140°F) -20°C to 80°C (-4°F to 176°F) -20°C to 60°C (-4°F to 140°F) -20°C to 50°C (-4°F to 122°F)
Accuracy Low to 10% H2 0.15% 0.3% 0.3% 0.3%
Accuracy 10 to 100% H2 N/A N/A 1% 1%
Drift / Week None None None None
Repeatability Low to 10% H2 0.15% 0.3% 0.2% 0.2%
Repeatability 10 to 100% H2 N/A N/A 0.4% 0.4%
Linearity Low to 10% H2 0.15% 0.3% 0.2% 0.2%
Linearity 10 to 100% H N/A N/A 0.4% 0.4%

Technical Information

Physical
  • Dimensions: 144.4 x 50 x 50 mm (5.68 x 1.97 x 1.97 in)
  • Weight: 748.43 g (1.65 lbs)
  • Electrical Fitting: TWELVE-PIN, M23
  • Sensor Fitting: M20 FACE SEAL, ISO 9974-1
Environmental
  • Ingress Protection: IP66
  • Operating Temperature: -20°C to 70°C (-4°F to 158°F)
  • Storage Temperature: -20°C to 105°C (-4°F to 221°F)
Power
  • Input Voltage: 10 to 15.6 VDC
  • Input Power: 2W
Performance
  • Operating Pressure (Hazardous Location): 0.95 - 1.1 ATM Absolute
  • Survival Pressure: 0.1 to 10 ATM Absolute
  • Flow Rate: 0.1 to 10 slpm (1/4” Tube) Operating Humidity: < 95% RH (non-condensing)
Communications
  • Digital Communication: MODBUS over RS-485, three-wire, half-duplex
  • Relays: 2 digital optocouplers
  • Analog: 4–20 mA

Request a Quote

H2Scan
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.