HY-ALERTA® 2620 Explosion Proof Area Hydrogen Monitor
Hydrogen Leak Detector - Explode Proof That Is Safe
- Measures from 4000 ppm to 5% hydrogen concentration
- Ceiling or wall mount options
- No cross-sensitivity/Avoids false alarms
Applications
H2scan’s 2620 Explosion Proof Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit. The monitor is designed for either ceiling or wall mount. H2scan’s hydrogen-specific sensor technology has no cross sensitivity to other combustible gases, thus eliminating false positive alarms and ensuring safety system reliability.
- Battery Rooms
- Control Rooms/Analyzer Buildings
- Laboratories
- Alternative Energy
- Hydrogen Cooled Generators and Turbines
- Industrial Gas Supply and Hydrogen Production
- Furnaces and Manufacturing
- Other Applications
Advantages
- Highly reliable
- Low life cycle cost
- Easy to install and operate
- Minimal maintenance required
- No cross sensitivity to combustible gases
- Not vulnerable to poisoning like other detectors
- Wide hydrogen-specific detection range
- Works in air, oxygen, or inert gas background
- Non-consumable solid state technology
- No cross sensitivity to combustible gases
- Not vulnerable to poisoning like other detectors
- Field-configurable settings
- Will not saturate with exposure to hydrogen
Configuration Details
Performance
- Hydrogen Sensitivity Range: 0.4% to 5.0% hydrogen by volume, 10% to 125% hydrogen lower flammable limit
- Response Time: T90 < 60 sec
- Ingress Protection: IP64 capable
- Calibration Interval: 90 days
- Product Life Expectancy: 10 years
- Accuracy: ± (3% of reading + 0.2) percent hydrogen by volume
Interface Options
- Input Voltage Range: 90 VAC to 240 VAC
- Input Power: 15W
- Analog Outputs:
- Output Currents
- 4 mA to 20 mA
- 0 mA to 20 mA
- User-specific mA range
- Output Currents
- Serial Communication Options: RS232 or RS422
- Relay Contacts: Two programmable relays and one fault relay with both normally open (N.O.) and normally closed (N.C.) contacts:
- 5A/240VAC
- 5A/ 30 VDC
Dimensions
- Width: 13.8 cm (5.4 in)
- Length: 19.2 cm (7.5 in)
- Depth: 13.0 cm (5.7 in)
Operating Conditions
- Operating Temperature Range: -20ºC to 55ºC
- Storage Temperature Range: -30ºC to 80ºC
- Operating Humidity: 0% to 95% RH (non-condensing)
- Calibration Background Gas: Air
Adapter Fittings
- 1/4 in. Tube for Calibration Gas Connection
Certifications
General | ![]() |
2620 |
|
Remote |
|
Technical Information
Physical |
|
Environmental |
|
Power |
|
Performance |
|