HY-SIGHT

Hydrogen Area Monitor Display and Controller

Overview

  • Centralized monitoring
  • Real-time measurement display
  • Relay outputs for safety systems
  • Visible and audible at the point of risk
  • Full system integration
  • Data and event management

The HY-SIGHT is a scalable platform that displays and configures HY-GUARD® hydrogen sensors, providing real-time monitoring and alarm notifications.

Key Advantages

  • Real-Time Hydrogen Monitoring
  • Configurable High Alarm
  • Data Logging & Historical Trends
  • MODBUS RTU Communication
  • User-Friendly Display and Controls
  • Seamless Facility Integration

Reliable Data for AI and Analytics

Proprietary self-monitoring technology continuously validates sensor performance, delivering clean, accurate data your AI and predictive maintenance initiatives demand. Unlike sensors that fail silently and corrupt your data record, H2scan sensors alert you immediately if performance degrades—ensuring every data point is reliable for both today’s monitoring needs and tomorrow’s analytics.

Applications

Lithium-Ion Battery

Standby Power Battery Rooms

Lead-Acid Battery Installations

NiCad Battery Systems

Battery Cabinets

Telecommunications Battery Backup

Data Center Standby Power

Emergency Power Systems

Utility Substations, Switchgear, SCADA

Hydrogen Economy

Forklift Batteries and Fuel Cells

Hydrogen Generation

Processing and Manufacturing

Commercial Maritime and Shipping

Medical Technologies and Complexes

Technical Information

Physical
  • Dimensions: 132.5 x 130.5 x 78.7 mm (5.1 x 5.1 x 3.1 in)
  • Weight: (0.5 kg) 1.1 lbs
  • Speaker: Audible output for local indication
  • Display: 2.1", 480×480 IPS with rotary encoder
Environmental
  • Operating Temperature: 3°C to 50°C (37°F to 122°F)
  • Storage Temperature: -20°C to 60°C (-4°F to 140°F)
  • Mounting: Wall Mount, Junction Box, or Punch Out
Power
  • Voltage Input AC: 85-264 VAC, 50/60 Hz
  • Voltage Input DC: 12 to 48 VDC
  • Power Consumption: 5 W max
Communications
  • RS-485 (Modbus RTU)
  • USB-C (Service)
Alarm Levels
  • Alarm 1 (Low) - 1.0% H2
  • Alarm 2 (High) - 2.0% H2
  • Fault - Sensor / System Fault

Certifications

Compliance & Certification*
  • IEC 61010
  • CE
  • FCC Part 15
  • REACH
  • RoHS
Applicable Standards
  • OSHA 29 CFR 1926
  • IFC 608/ Chapter 12
  • NFPA 1 & 855
  • NFPA 68 & 69
  • IEC 62933
  • IEEE Standards – Stationary battery and energy storage

*NOTE: All certifications pending

Request a Quote

H2scan
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.